2022-07-25 17:08:12 +00:00
@ setlocal DisableDelayedExpansion
@ echo off
: :============================================================================
: :
: : This script is a part of 'Microsoft Activation Scripts' (MAS) project.
: :
: : Homepage: windowsaddict.ml
: : Email: windowsaddict@protonmail.com
: :
: :============================================================================
: : For unattended mode, run the script with /u parameter.
: :========================================================================================================================================
: : Re-launch the script with x64 process if it was initiated by x86 process on x64 bit Windows
: : or with ARM64 process if it was initiated by x86/ARM32 process on ARM64 Windows
if exist %SystemRoot% \Sysnative\cmd.exe (
set " _cmdf= %~f0 "
setlocal EnableDelayedExpansion
start %SystemRoot% \Sysnative\cmd.exe /c " " !_cmdf! " %* "
exit /b
)
: : Re-launch the script with ARM32 process if it was initiated by x64 process on ARM64 Windows
if exist %SystemRoot% \SysArm32\cmd.exe if %PROCESSOR_ARCHITECTURE% == AMD64 (
set " _cmdf= %~f0 "
setlocal EnableDelayedExpansion
start %SystemRoot% \SysArm32\cmd.exe /c " " !_cmdf! " %* "
exit /b
)
: : Set Path variable, it helps if it is misconfigured in the system
set " SysPath= %SystemRoot% \System32 "
if exist " %SystemRoot% \Sysnative\reg.exe " ( set " SysPath= %SystemRoot% \Sysnative " )
set " Path= %SysPath% ; %SystemRoot% ; %SysPath% \Wbem; %SysPath% \WindowsPowerShell\v1.0\ "
: :========================================================================================================================================
cls
color 07
title Install Windows 10-11 Retail/MAK/OEM Key
set _args =
set _elev =
set _unattended = 0
set _args = %*
if defined _args set _args = %_args:"=%
if defined _args (
for %% A in ( %_args% ) do (
if /i " %% A " == " -el " set _elev = 1
if /i " %% A " == " /u " set _unattended = 1
)
)
: :========================================================================================================================================
set winbuild = 1
set " nul=>nul 2>&1 "
set " _psc= %SystemRoot% \System32\WindowsPowerShell\v1.0\powershell.exe "
for /f " tokens=6 delims=[]. " %% G in ( 'ver' ) do set winbuild = %% G
set _NCS = 1
if %winbuild% LSS 10586 set _NCS = 0
if %winbuild% GEQ 10586 reg query " HKCU\Console " /v ForceV2 2 > nul | find /i " 0x0 " 1 > nul && ( set _NCS = 0)
if %_NCS% EQU 1 (
for /F %% a in ( 'echo prompt $E ^| cmd' ) do set " esc= %% a "
set " Red= " 41;97m" "
set " Green= " 42;97m" "
set " _Green= " 40;92m" "
set " _Yellow= " 40;93m" "
) else (
set " Red= " Red" " white" "
set " Green= " DarkGreen" " white" "
set " _Green= " Black" " Green" "
set " _Yellow= " Black" " Yellow" "
)
set " nceline=echo: &echo ==== ERROR ==== &echo: "
set " eline=echo: &call :dk_color %Red% " ==== ERROR ====" &echo: "
set slp = SoftwareLicensingProduct
set sls = SoftwareLicensingService
set wApp = 55c92734-d682-4d71-983e-d6ec3f16059f
set " line=echo ___________________________________________________________________________________________ "
: :========================================================================================================================================
if %winbuild% LSS 10240 (
%eline%
echo Unsupported OS version detected.
echo Project is supported for Windows 10/11.
goto ins_done
)
if %winbuild% GEQ 22483 if not exist %_psc% (
%nceline%
echo Powershell is not installed in the system.
goto ins_done
)
: :========================================================================================================================================
: : Fix for the special characters limitation in path name
set " _batf= %~f0 "
set " _batp= %_batf:'=''% "
set " _PSarg= " " " %~f0 " " " -el %_args% "
set " _ttemp= %temp% "
setlocal EnableDelayedExpansion
: :========================================================================================================================================
echo " !_batf! " | find /i " !_ttemp! " 1 > nul && (
%eline%
echo Script is launched from the temp folder,
echo Most likely you are running the script directly from the archive file.
echo :
echo Extract the archive file and launch the script from the extracted folder.
goto ins_done
)
: :========================================================================================================================================
: : Elevate script as admin and pass arguments and preventing loop
%nul% reg query HKU\S-1-5-19 || (
if not defined _elev %nul% %_psc% " start cmd.exe -arg '/c \ " !_PSarg:'=''! \" ' -verb runas " && exit /b
%eline%
echo This script require administrator privileges.
echo To do so, right click on this script and select 'Run as administrator'.
goto ins_done
)
: :========================================================================================================================================
mode 98, 30
echo :
echo Initializing...
: : Check WMI and sppsvc Errors
set applist =
net start sppsvc /y %nul%
if %winbuild% LSS 22483 set " chkapp=for /f " tokens=2 delims==" %% a in (' " wmic path %slp% where (ApplicationID='%wApp% ') get ID /VALUE" 2 ^ >nul') "
if %winbuild% GEQ 22483 set " chkapp=for /f " tokens=2 delims==" %% a in (' %_psc% " (([WMISEARCHER]'SELECT ID FROM %slp% WHERE ApplicationID=''%wApp% ''').Get()).ID ^| %% {echo ('ID='+$_)}" 2 ^ >nul') "
%chkapp% do (if defined applist (call set " applist=!applist! %% a " ) else (call set " applist= %% a " ))
if not defined applist (
%eline%
echo Failed running WMI query check, verify that these services are working correctly
echo Windows Management Instrumentation [WinMgmt], Software Protection [sppsvc]
echo :
echo Script will try to enable these services.
echo :
if %_unattended% == 0 (
call : dk_color %_Yellow% " Press any key to continue... "
pause > nul
)
for /f " skip=2 tokens=2* " %% a in ( 'reg query HKLM\SYSTEM\CurrentControlSet\Services\WinMgmt /v Start 2^>nul' ) do if /i %% b equ 0x4 ( sc config WinMgmt start= auto %nul% )
net start WinMgmt /y %nul%
net stop sppsvc /y %nul%
net start sppsvc /y %nul%
cls
)
: :========================================================================================================================================
: : Refresh license status, it helps to get correct product name in Windows 17134 and later builds
call : dk_refresh
: : Check product name
set winos =
for /f " skip=2 tokens=2* " %% a in ( 'reg query "HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion" /v ProductName 2^>nul' ) do set " winos= %% b "
: :========================================================================================================================================
: : Check SKU value
set osSKU =
for /f " tokens=3 delims=. " %% a in ( 'reg query "HKLM\SYSTEM\CurrentControlSet\Control\ProductOptions" /v OSProductPfn 2^>nul' ) do set " osSKU= %% a "
if not defined osSKU (
%eline%
echo SKU value was not detected properly. Aborting...
goto ins_done
)
: :========================================================================================================================================
: : Detect key
set key =
set _chan =
if defined applist call : hwiddata attempt1
if not defined key call : hwiddata attempt2
if not defined key (
%eline%
echo Unable to find Key for [%winos% ^| SKU:%osSKU% ^| %winbuild% ]
if %winbuild% GTR 19044 echo Make sure you are using updated version of the script
goto ins_done
)
: :========================================================================================================================================
if %_unattended% == 1 goto insertkey
cls
%line%
echo :
echo Install [%winos% ^| SKU:%osSKU% ^| %winbuild% ] %_chan% Key
echo [%key% ]
%line%
echo :
call : dk_color %_Green% " Press [1] to Continue or [2] to Exit "
choice /C:21 /N
if %errorlevel% == 1 exit /b
cls
: :========================================================================================================================================
: insertkey
cls
%line%
if %winbuild% LSS 22483 wmic path %sls% where __CLASS='%sls% ' call InstallProductKey ProductKey=" %key% " %nul%
if %winbuild% GEQ 22483 %_psc% " (([WMISEARCHER]'SELECT Version FROM %sls% ').Get()).InstallProductKey(' %key% ') " %nul%
if not %errorlevel% == 0 cscript //nologo %windir% \system32\slmgr.vbs /ipk %key% %nul%
if %errorlevel% == 0 (
call : dk_refresh
echo :
echo [%winos% ^| SKU:%osSKU% ^| %winbuild% ]
echo Installing %_chan% Key [%key% ]
echo :
call : dk_color %Green% " [Successful] "
) else (
%eline%
echo [%winos% ^| SKU:%osSKU% ^| %winbuild% ]
echo Installing %_chan% Key [%key% ]
echo :
call : dk_color %Red% " [Unsuccessful] %actidnotfound% "
)
%line%
: :========================================================================================================================================
: ins_done
echo :
if %_unattended% == 1 timeout /t 2 & exit /b
call : dk_color %_Yellow% " Press any key to exit... "
pause > nul
exit /b
: :========================================================================================================================================
: : Refresh license status
: dk_refresh
if %winbuild% LSS 22483 wmic path %sls% where __CLASS='%sls% ' call RefreshLicenseStatus %nul%
if %winbuild% GEQ 22483 %_psc% " $null=(([WMICLASS]' %sls% ').GetInstances()).RefreshLicenseStatus() " %nul%
exit /b
: :========================================================================================================================================
: dk_color
if %_NCS% EQU 1 (
echo %esc% [%~1 %~2 %esc% [0m
) else (
if not exist %_psc% ( echo %~3 ) else ( %_psc% write-host -back '%1 ' -fore '%2 ' '%3 ')
)
exit /b
: :========================================================================================================================================
: : 1st column = Activation ID
: : 2nd column = Generic Retail/OEM/MAK Key
: : 3rd column = SKU ID
: : 4th column = 1 = activation is not working (at the time of writing this), 0 = activation is working
: : 5th column = Key Type
: : 6th column = WMI Edition ID
: : 7th column = Version name incase same Edition ID is used in different OS versions with different key
: : Separator = _
: : Key preference is in the following order. Retail > OEM:NONSLP > OEM:DM > Volume:MAK
: hwiddata
for %% # in (
8b351c9c-f398-4515-9900-09df49427262_XGVPP-NMH47-7TTHJ-W3FW7-8HV2C___4_0_OEM:NONSLP_Enterprise
23505d51-32d6-41f0-8ca7-e78ad0f16e71_D6RD9-D4N8T-RT9QX-YW6YT-FCWWJ__11_1_____Retail_Starter
c83cef07-6b72-4bbc-a28f-a00386872839_3V6Q6-NQXCX-V8YXR-9QCYV-QPFCT__27_0_Volume:MAK_EnterpriseN
211b80cc-7f64-482c-89e9-4ba21ff827ad_3NFXW-2T27M-2BDW6-4GHRV-68XRX__47_1_____Retail_StarterN
4de7cb65-cdf1-4de9-8ae8-e3cce27b9f2c_VK7JG-NPHTM-C97JM-9MPGT-3V66T__48_0_____Retail_Professional
9fbaf5d6-4d83-4422-870d-fdda6e5858aa_2B87N-8KFHP-DKV6R-Y2C8J-PKCKT__49_0_____Retail_ProfessionalN
f742e4ff-909d-4fe9-aacb-3231d24a0c58_4CPRK-NM3K3-X6XXQ-RXX86-WXCHW__98_0_____Retail_CoreN
1d1bac85-7365-4fea-949a-96978ec91ae0_N2434-X9D7W-8PF6X-8DV9T-8TYMD__99_0_____Retail_CoreCountrySpecific
3ae2cc14-ab2d-41f4-972f-5e20142771dc_BT79Q-G7N6G-PGBYW-4YWX6-6F4BT_100_0_____Retail_CoreSingleLanguage
2b1f36bb-c1cd-4306-bf5c-a0367c2d97d8_YTMG3-N6DKC-DKB77-7M9GH-8HVX7_101_0_____Retail_Core
2a6137f3-75c0-4f26-8e3e-d83d802865a4_XKCNC-J26Q9-KFHD2-FKTHY-KD72Y_119_0_OEM:NONSLP_PPIPro
e558417a-5123-4f6f-91e7-385c1c7ca9d4_YNMGQ-8RYV3-4PGQ3-C8XTP-7CFBY_121_0_____Retail_Education
c5198a66-e435-4432-89cf-ec777c9d0352_84NGF-MHBT6-FXBX8-QWJK7-DRR8H_122_0_____Retail_EducationN
cce9d2de-98ee-4ce2-8113-222620c64a27_KCNVH-YKWX8-GJJB9-H9FDT-6F7W2_125_1_Volume:MAK_EnterpriseS_2021
d06934ee-5448-4fd1-964a-cd077618aa06_43TBQ-NH92J-XKTM7-KT3KK-P39PB_125_0_OEM:NONSLP_EnterpriseS_2019
706e0cfd-23f4-43bb-a9af-1a492b9f1302_NK96Y-D9CD8-W44CQ-R8YTK-DYJWX_125_0_OEM:NONSLP_EnterpriseS_2016
faa57748-75c8-40a2-b851-71ce92aa8b45_FWN7H-PF93Q-4GGP8-M8RF3-MDWWW_125_0_OEM:NONSLP_EnterpriseS_2015
2c060131-0e43-4e01-adc1-cf5ad1100da8_RQFNW-9TPM3-JQ73T-QV4VQ-DV9PT_126_1_Volume:MAK_EnterpriseSN_2021
e8f74caa-03fb-4839-8bcc-2e442b317e53_M33WV-NHY3C-R7FPM-BQGPT-239PG_126_1_Volume:MAK_EnterpriseSN_2019
3d1022d8-969f-4222-b54b-327f5a5af4c9_2DBW3-N2PJG-MVHW3-G7TDK-9HKR4_126_0_Volume:MAK_EnterpriseSN_2016
60c243e1-f90b-4a1b-ba89-387294948fb6_NTX6B-BRYC2-K6786-F6MVQ-M7V2X_126_0_Volume:MAK_EnterpriseSN_2015
a48938aa-62fa-4966-9d44-9f04da3f72f2_G3KNM-CHG6T-R36X3-9QDG6-8M8K9_138_1_____Retail_ProfessionalSingleLanguage
f7af7d09-40e4-419c-a49b-eae366689ebd_HNGCC-Y38KG-QVK8D-WMWRK-X86VK_139_1_____Retail_ProfessionalCountrySpecific
eb6d346f-1c60-4643-b960-40ec31596c45_DXG7C-N36C4-C4HTG-X4T3X-2YV77_161_0_____Retail_ProfessionalWorkstation
89e87510-ba92-45f6-8329-3afa905e3e83_WYPNQ-8C467-V2W6J-TX4WX-WT2RQ_162_0_____Retail_ProfessionalWorkstationN
62f0c100-9c53-4e02-b886-a3528ddfe7f6_8PTT6-RNW4C-6V7J2-C2D3X-MHBPB_164_0_____Retail_ProfessionalEducation
13a38698-4a49-4b9e-8e83-98fe51110953_GJTYN-HDMQY-FRR76-HVGC7-QPF8P_165_0_____Retail_ProfessionalEducationN
1ca0bfa8-d96b-4815-a732-7756f30c29e2_FV469-WGNG4-YQP66-2B2HY-KD8YX_171_1_OEM:NONSLP_EnterpriseG
8d6f6ffe-0c30-40ec-9db2-aad7b23bb6e3_FW7NV-4T673-HF4VX-9X4MM-B4H4T_172_1_OEM:NONSLP_EnterpriseGN
df96023b-dcd9-4be2-afa0-c6c871159ebe_NJCF7-PW8QT-3324D-688JX-2YV66_175_0_____Retail_ServerRdsh
d4ef7282-3d2c-4cf0-9976-8854e64a8d1e_V3WVW-N2PV2-CGWC3-34QGF-VMJ2C_178_0_____Retail_Cloud
af5c9381-9240-417d-8d35-eb40cd03e484_NH9J3-68WK7-6FB93-4K3DF-DJ4F6_179_0_____Retail_CloudN
c7051f63-3a76-4992-bce5-731ec0b1e825_2HN6V-HGTM8-6C97C-RK67V-JQPFD_183_1_____Retail_CloudE
8ab9bdd1-1f67-4997-82d9-8878520837d9_XQQYW-NFFMW-XJPBH-K8732-CKFFD_188_0_____OEM:DM_IoTEnterprise
ed655016-a9e8-4434-95d9-4345352c2552_QPM6N-7J2WJ-P88HH-P3YRH-YY74H_191_0_OEM:NONSLP_IoTEnterpriseS
d4bdc678-0a4b-4a32-a5b3-aaa24c3b0f24_K9VKN-3BGWV-Y624W-MCRMQ-BHDCD_202_0_____Retail_CloudEditionN
92fb8726-92a8-4ffc-94ce-f82e07444653_KY7PN-VR6RX-83W6Y-6DDYQ-T6R4W_203_0_____Retail_CloudEdition
) do (
for /f " tokens=1-7 delims=_ " %% A in ( " %% # " ) do if %osSKU% == %% C (
if %1 == attempt1 if not defined key echo " !applist! " | find /i " %% A " 1 > nul && ( set " key= %% B " & set " _chan= %% E " & if %% D== 1 set notworking = 1)
if %1 == attempt2 if not defined key (
set " actidnotfound= [Mismatched Act-ID] "
set 7th = %% G
if not defined 7th (
set " key= %% B " & set " _chan= %% E " & if %% D== 1 set notworking = 1
) else (
echo " %winos% " | find " %% G " 1 > nul && ( set " key= %% B " & set " _chan= %% E " & if %% D== 1 set notworking = 1)
)
)
)
)
exit /b
2022-01-23 23:28:16 +00:00
: :========================================================================================================================================